Cogenon TPP CO 50 LH-EG/FG

Das Cogenon 50  kW Aggregat


The advantages of the CO 50 kW thermal power plant at a glance


  • Greatly reduced CO2 emissions and lower energy costs
    thanks to its highly efficient operation
  • Excellent efficiency rating
    thanks to the optimal use of primary fuel
  • Höchste Lebensdauer
    thanks to its straight 6-cylinder industrial motor with specially selected components
  • Excellent operational reliability
    thanks to the high-torque engine
  • Low-vibration operation
    with the help of damping elements
  • Surpasses all relevant emission standards
    the TA-Luft-Standard for this performance class
  • Easy to fit
    thanks to its compact, integrated design only 800 mm wide
  • Easy to install
    thanks to Plug-and-Play-components
  • Optimal integration with existing heating systems
    thanks to the total integration of existing furnaces (furnace approval)
  • Easy intuitive operation
    thanks to its graphical LC display
  • • Very service-friendly and low maintenance costs
    thanks to the service doors in the noise damping housing

 

General data
  CO 50 LH (all fuels)
Motortype
Liebherr
Cylinder 4 (straight)
Displacement (cm3) 6640
Rated speed (min-1) 1500
Voltage (V)
3 x 230/400
Frequency (Hz)
50
cos φ
0,8 - 1
Dimensions LxWxH (mm) 2800 x 800 x 1900 (3200 x 900 x 2000)
max. send temperature (°C)
85
max. return temperature (°C) 75
Connectors send and return (DN)
40
Connector exhaust pipe (DN) 100
Conformity TÜV / DVGW / CE / TA-Luft

 

Detailed data according to fuel type used
  CO 50 LH-EG
CO 50 LH-FG
Fuel Natural gas Liquefied gas
Motor type
G 924S
G 924S
Possible operation modes 1 NP/I/NE NP/I/NE
Fuel norm - -
Gas pressure (mbar) 20 - 100 20 - 100
Performance control (%)
50 - 100 50 - 100
Pressure in heating system (bar)
4
4 
Energy consumption (kW +/- 5%) 2 155 155
Output electr. (kW +/- 5%) 3
50 50
Output therm. (kW +/- 5%) 4 88 88
Efficiency rating electr. (%) 32.2 32.2
Efficiency rating therm. (%)
56.8 56.8
Total efficiency rating (%) 89 89
Electrical performance index 0.57 0.57
Sound pressure level (dB/A in 1 m) 5
78 (63)
77 (63)
Total weight (kg)   2430 2430

1 NP – Mains parallel mode, I – Isolated mode, NE – mains replacement mode
2 Motor performance according to ISO 3046/1 and DIN 6271 at 25°C surrounding temperature: 100 kPa
3 At 1500 min-1, 50 Hz, 400 V, cos φ=1
4 Exhaust cooling to 120 °C
5 Sound pressure module (exhaust)

 

Downloads
Data sheet
Cogenon BHKW CO 50 LH-EG/FG
pdf_button